|
|
Registro Completo |
Biblioteca(s): |
Embrapa Acre. |
Data corrente: |
22/11/2023 |
Data da última atualização: |
22/11/2023 |
Tipo da produção científica: |
Resumo em Anais de Congresso |
Autoria: |
PEREIRA, J. E. S.; OLIVEIRA, J. P.; SCHMITZ, G. C. B.; COSTA, F. H. S.; SOUZA, G. E. de; ALVES, L. S.; MACHADO, B. J. A. |
Afiliação: |
JONNY EVERSON SCHERWINSKI PEREIRA, CPAF-AC; J. P. OLIVEIRA, BOLSISTA PIBIC/CNPq/DTI/CNPq/EMBRAPA ACRE; G. C. B. SCHMITZ, BOLSISTA PIBIC/CNPq/DTI/CNPq/EMBRAPA ACRE; FREDERICO HENRIQUE SILVA COSTA, BOLSISTA PIBIC/CNPq/DTI/CNPq/EMBRAPA ACRE; GILDO EREMITH DE SOUZA, CPAF-AC; L. S. ALVES, BOLSISTA PIBIC/CNPq/DTI/CNPq/EMBRAPA ACRE; BIANOR JUNIOR ALVES MACHADO, CPAF-AC. |
Título: |
Determinação de taxas de multiplicação e estimativa de produção de mudas de bananeira por micropropagação, cvs. Pacovan Ken e Japira. |
Ano de publicação: |
2006 |
Fonte/Imprenta: |
In: CONGRESSO BRASILEIRO DE FRUTICULTURA, 19., 2006, Cabo Frio, RJ. Frutas do Brasil: saúde para o mundo: palestras e resumos. Cabo Frio, RJ: UENF: UFRRJ, 2006. |
Páginas: |
p. 169. |
Idioma: |
Português |
Conteúdo: |
O objetivo do trabalho foi determinar as taxas de multiplicação e estimar a produção de mudas de bananeira por micropropagação, das cultivares Pacovan Ken e Japira. |
Palavras-Chave: |
Estimación; Japira; Micropropagación; Pacovan Ken; Producción de plántulas. |
Thesagro: |
Banana; Estimativa; Micropropagação; Muda; Musa sp; Produção. |
Thesaurus Nal: |
Estimation; Micropropagation; Seedling production. |
Categoria do assunto: |
G Melhoramento Genético |
Marc: |
LEADER 01325nam a2200361 a 4500 001 2158644 005 2023-11-22 008 2006 bl uuuu u00u1 u #d 100 1 $aPEREIRA, J. E. S. 245 $aDeterminação de taxas de multiplicação e estimativa de produção de mudas de bananeira por micropropagação, cvs. Pacovan Ken e Japira.$h[electronic resource] 260 $aIn: CONGRESSO BRASILEIRO DE FRUTICULTURA, 19., 2006, Cabo Frio, RJ. Frutas do Brasil: saúde para o mundo: palestras e resumos. Cabo Frio, RJ: UENF: UFRRJ$c2006 300 $ap. 169. 520 $aO objetivo do trabalho foi determinar as taxas de multiplicação e estimar a produção de mudas de bananeira por micropropagação, das cultivares Pacovan Ken e Japira. 650 $aEstimation 650 $aMicropropagation 650 $aSeedling production 650 $aBanana 650 $aEstimativa 650 $aMicropropagação 650 $aMuda 650 $aMusa sp 650 $aProdução 653 $aEstimación 653 $aJapira 653 $aMicropropagación 653 $aPacovan Ken 653 $aProducción de plántulas 700 1 $aOLIVEIRA, J. P. 700 1 $aSCHMITZ, G. C. B. 700 1 $aCOSTA, F. H. S. 700 1 $aSOUZA, G. E. de 700 1 $aALVES, L. S. 700 1 $aMACHADO, B. J. A.
Download
Esconder MarcMostrar Marc Completo |
Registro original: |
Embrapa Acre (CPAF-AC) |
|
Biblioteca |
ID |
Origem |
Tipo/Formato |
Classificação |
Cutter |
Registro |
Volume |
Status |
URL |
Voltar
|
|
| Acesso ao texto completo restrito à biblioteca da Embrapa Pecuária Sudeste. Para informações adicionais entre em contato com cppse.biblioteca@embrapa.br. |
Registro Completo
Biblioteca(s): |
Embrapa Pecuária Sudeste. |
Data corrente: |
07/07/2021 |
Data da última atualização: |
28/09/2021 |
Tipo da produção científica: |
Artigo em Periódico Indexado |
Circulação/Nível: |
A - 2 |
Autoria: |
SILVA, A. B. S. do; SÁ, I. P. de; MARCANO DE HIGUERA, J.; NOGUEIRA, A. R. de A. |
Afiliação: |
ANA BEATRIZ SANTOS DA SILVA, UFSCAR; ÍVERO PITA DE SÁ, UFSCAR; JULYMAR MARCANO DE HIGUERA, UFSCAR; ANA RITA DE ARAUJO NOGUEIRA, CPPSE. |
Título: |
Feasibility of dispersive liquid-liquid microextraction for molybdenum determination in lamb meat by MIP OES. |
Ano de publicação: |
2021 |
Fonte/Imprenta: |
Food Analytical Methods, v.14, 2021. |
Páginas: |
p.496-502. |
ISSN: |
1936-976X |
DOI: |
https://doi.org/10.1007/s12161-020-01898-x |
Idioma: |
Inglês |
Conteúdo: |
The dispersive liquid?liquid microextraction (DLLME) was evaluated as a strategy to improve the MIP OES sensitivity for molybdenum determination in lamb meat. Initially, the dispersive (methanol) and extracting (tetrachloromethane) solvents were selected based on a mixture design. The best results were achieved with methanol and carbon tetrachloride as dispersive and extracting solvent, respectively. The operational parameters, such as pH, volume of dispersive and extractant solvents, and complexing agent concentration (8-hydroxyquinoline) were optimized using a Box-Behnken design. The optimal conditions were established as pH 3.8, 90 uL of carbon tetrachloride, 480 uL of methanol, and 1.09 mmol L-1 of 8-hydroxyquinoline. Besides, the use of external gas module control (EGCM) was explored to minimize the matrix effects caused by the organic solvent introduction. The accuracy of the proposed method was estimated employing a certificate reference material (bovine liver, NIST 1577c) and the obtained recovery was 92%. The limit of detection was found to be 0.20 ug g-1, and the enrichment factor was 4.5. The DLLME-MIP OES was applied for six samples of lamb meat, and the results compared to ICP-MS presented no statistical difference. Therefore, the proposed method showed satisfactory accuracy and suitable sensitivity. |
Palavras-Chave: |
DLLME; MIP OES; Sample preparation; Trace analysis. |
Thesaurus NAL: |
Microextraction. |
Categoria do assunto: |
W Química e Física |
Marc: |
LEADER 02099naa a2200253 a 4500 001 2132839 005 2021-09-28 008 2021 bl uuuu u00u1 u #d 022 $a1936-976X 024 7 $ahttps://doi.org/10.1007/s12161-020-01898-x$2DOI 100 1 $aSILVA, A. B. S. do 245 $aFeasibility of dispersive liquid-liquid microextraction for molybdenum determination in lamb meat by MIP OES.$h[electronic resource] 260 $c2021 300 $ap.496-502. 520 $aThe dispersive liquid?liquid microextraction (DLLME) was evaluated as a strategy to improve the MIP OES sensitivity for molybdenum determination in lamb meat. Initially, the dispersive (methanol) and extracting (tetrachloromethane) solvents were selected based on a mixture design. The best results were achieved with methanol and carbon tetrachloride as dispersive and extracting solvent, respectively. The operational parameters, such as pH, volume of dispersive and extractant solvents, and complexing agent concentration (8-hydroxyquinoline) were optimized using a Box-Behnken design. The optimal conditions were established as pH 3.8, 90 uL of carbon tetrachloride, 480 uL of methanol, and 1.09 mmol L-1 of 8-hydroxyquinoline. Besides, the use of external gas module control (EGCM) was explored to minimize the matrix effects caused by the organic solvent introduction. The accuracy of the proposed method was estimated employing a certificate reference material (bovine liver, NIST 1577c) and the obtained recovery was 92%. The limit of detection was found to be 0.20 ug g-1, and the enrichment factor was 4.5. The DLLME-MIP OES was applied for six samples of lamb meat, and the results compared to ICP-MS presented no statistical difference. Therefore, the proposed method showed satisfactory accuracy and suitable sensitivity. 650 $aMicroextraction 653 $aDLLME 653 $aMIP OES 653 $aSample preparation 653 $aTrace analysis 700 1 $aSÁ, I. P. de 700 1 $aMARCANO DE HIGUERA, J. 700 1 $aNOGUEIRA, A. R. de A. 773 $tFood Analytical Methods$gv.14, 2021.
Download
Esconder MarcMostrar Marc Completo |
Registro original: |
Embrapa Pecuária Sudeste (CPPSE) |
|
Biblioteca |
ID |
Origem |
Tipo/Formato |
Classificação |
Cutter |
Registro |
Volume |
Status |
Fechar
|
Nenhum registro encontrado para a expressão de busca informada. |
|
|